Checking the adequacy of mathematical models thermal power facilities

Abstract

Checking the adequacy of mathematical models thermal power facilities

Shevchuk V.P., Eremina E.L., Silaeva E.Yu.

Incoming article date: 28.05.2019

The work is devoted to the development of an adequate model of a steam drum unit that will allow the development of an optimal control algorithm. The causal relationships of the boiler unit were considered and their transfer functions were given. Mathematical models of the steam drum boiler experimental, based on the removal of the acceleration curves, and the combined methods were also obtained.

Keywords: analysis of control algorithms, adequate models, mathematical models